How does the surface sensor calibrator control system operate?

Release time:2022-12-13    This article is read 5336 Times

How does the surface sensor calibrator control system operate?

The Control system can automatically connect to the Surface sensor calibrator, monitor the data of the surface calibrator in real time and control the Surface sensor calibrator.

The Surface sensor calibrator Control System supports the following functions:

1. Display and refresh the device PV value in real time.

2. Display the device Sv value and set the device Sv value.

3. Automatically calculate and display the 10-minute fluctuation of the equipment.

4. Start/stop Surface calibrator temperature control.

5. Start/stop Surface calibrator autotune.

6. Display the surface probe calibrator curve in real time, and support zooming and panning functions. 

System Configuration

? After the system starts, enter the Surface sensor calibrator control configuration interface.

? In the configuration interface, select the communication port of the surface probe calibrator device according to the serial port connection.

? The communication rate of the surface calibrator is 115200, and the communication format of the surface probe calibrator is 8N1, which does not need to be modified.

? Click the start button, the system will automatically connect to the Surface sensor calibrator.

surface sensor calibrator control system

Surface sensor calibrator connection

? The system enters the Surface sensor calibrator connection interface and starts online inspection of surface calibrator  equipment.

? If the serial port of the surface probe calibrator program is occupied, it will return to the configuration interface, and an error message of "communication port is occupied" will be prompted.

surface sensor calibrator control system

If the Surface sensor calibrator program does not respond, it will return to the configuration interface and prompt the error message "Surface calibrator does not respond".

surface sensor calibrator control system

If the Surface sensor calibrator program connection is successful, it will enter the monitoring main interface.

Monitoring main interface

? After the system enters the monitoring main interface, it will display Pv value, Sv value, 10-minute fluctuation and record curve information.

? The system collects Pv value data in real time and refreshes it in real time on the main interface.

? The system displays the current Sv value, and the Sv value can be modified by setting the temperature button.

? When the system starts 10 minutes later, it starts to display the 10-minute fluctuation of the surface probe calibrator. If the system startup time is less than 10 minutes, it will display --.

? The system collects data every 5s, and adds the data to the historical record. The 10-minute fluctuation data is obtained by calculating the historical record data. After the historical record data is added, it will be displayed in the historical record curve in real time.

surface sensor calibrator control system

Record curve

The temperature curve of the last 10 minutes is displayed in real time in the record curve. When new data is added to the history record, the record curve will be refreshed in real time.

? In the record curve, click the enter interactive mode button on the upper right to enter the record curve interactive mode. In the interactive mode, the record curve can be zoomed in, zoomed out, panned, displayed all data, refreshed data, and displayed/hidden prompt information.

surface sensor calibrator control system

? Curve zoom in and zoom out: In the interactive mode, scroll the mouse wheel up to zoom out the curve. Roll the wheel down to zoom in on the curve.

? Curve translation: In interactive mode, hold down the left mouse button and drag to perform curve translation.

? Show All: In the interactive mode, click the Show All button to automatically zoom the curve to ensure that all data can be displayed correctly in the chart.

? Refresh chart: In the interactive mode, click Refresh Chart, and the system will refresh the data to ensure that the newly collected data can be displayed correctly.

? Show/Hide Prompt Information: In interactive mode, uncheck the "Show Prompt Information" check box, and the prompt information of each data collection point will no longer be displayed. Select the "Show Prompt Information" check box, and when you move the mouse, it will automatically prompt the collection date, collection time and data value of the latest collection point.

Surface sensor calibrator Control

? Surface probe calibrator control operation support: start/stop temperature control, start/stop setting, modify set value Sv.

? Start/stop temperature control: Click the start temperature control button, and the system enters the temperature control mode. In the temperature control mode, only the operation of stopping the temperature control can be performed, and other verification furnace control operations cannot be performed. Click the stop temperature control button to pop up a confirmation dialog box for stopping temperature control, click OK to exit the temperature control mode.

surface sensor calibrator control system

surface sensor calibrator control system

Start/stop tuning: Click the start tuning button, the system will pop up a confirmation dialog box, enter the self-tuning password to enter the self-tuning mode. In the self-tuning mode, only the operation of stopping the self-tuning can be performed, and other verification furnace control operations cannot be performed. Click the stop tuning button to exit the auto-tuning mode.

Note: Please use the self-tuning function after consulting the manufacturer.

surface sensor calibrator control system

surface sensor calibrator control system

surface sensor calibrator control system

Modify the set value Sv: click the set temperature button, a dialog box for modifying the set temperature will pop up, modify the set temperature value, and click the set button to modify the set temperature of the surface probe calibrator.

surface sensor calibrator control system

Note: When the system is in the temperature control mode/setting mode, the set value Sv cannot be modified, it must be modified after the temperature control/auto-tuning is stopped.

Stop monitoring: click the stop monitoring button, a dialog box of stopping monitoring will pop up, click stop, and the system will exit the monitoring interface.

surface sensor calibrator control system


How does the surface sensor calibrator control system operate?
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:The difference between liquid calibration bath and dry block calibratornext:Invitation: Join Us at World Metrology Day 2026 Conference in Singapore

Contact us

DEARTO QR codeHeadquarter Address Tai'an High-tech Development Zone,  Shandong Province 
Telephon :+86 0538-5089056  +86 13953856217 
Fax : +86 0538-5059718 
After sale:+86 0538-5050959
Website : www.tadt.com.cn 
E-mail   :  tadtzdh@dearto.cn

Copyright? Tai'an Detu Automation Instrument Co., Ltd.             Lu ICP 14024757-1           Business license inquiry

主站蜘蛛池模板: 日韩三级免费观看 | 黄色毛片视频 | 久久婷婷国产色一区二区三区 | 一二三区av | 欧美激情精品久久久久 | 亚洲免费在线观看视频 | 久久久久成人精品亚洲国产 | 日韩免费一区 | 国产蜜臀av | 精品免费视频 | 丁香av在线 | 婷婷丁香社区 | 欧美在线观看视频 | 中文字幕制服丝袜av久久 | 国产黄色免费在线观看 | 色综合久久88 | 国产1区2区3区在线 亚洲自拍偷拍色图 | 波多野结衣视频网址 | 性色av免费观看 | 超碰精品在线观看 | 麻豆高清免费国产一区 | 91视频 - 114av | avhd高清在线谜片 | 亚洲日本va中文字幕 | 中文字幕在线看视频 | 六月丁香婷 | 免费在线h| 天天干人人插 | 久久www免费人成看片高清 | 伊人手机在线 | 在线观看岛国 | 国产99在线播放 | 中文字幕永久 | 亚洲精品美女免费 | 国产在线观看高清视频 | 国产一区二区在线播放视频 | 啪啪精品 | 丁香六月网 | 婷婷激情综合五月天 | 亚洲情婷婷 | 美女很黄免费网站 | 国产 欧美 在线 | 婷婷在线免费视频 | 国产精品久久中文字幕 | 免费99视频 | 午夜久久福利影院 | 看污网站| 亚洲精品视频免费在线 | 日韩理论片中文字幕 | 91免费网站在线观看 | 国产精品v a免费视频 | 青青河边草观看完整版高清 | 丁香六月综合网 | 在线影院 国内精品 | 2020天天干天天操 | 天天爱天天射 | 韩国在线视频一区 | 黄色三级免费网址 | 国产精品久久久999 国产91九色视频 | 久久久久久久久久久久久久免费看 | 2024国产精品视频 | a级国产乱理伦片在线播放 久久久久国产精品一区 | 免费看的黄网站软件 | 国产精品久久久久久高潮 | 亚洲精品网站 | 毛片网站免费在线观看 | 日韩免费在线播放 | 久久久观看 | 伊人va| 操操操操网 | av韩国在线| 国产成人黄色网址 | 久久国产精品二国产精品中国洋人 | 99久久日韩精品免费热麻豆美女 | 久久久人| 午夜视频在线观看欧美 | 91看片在线免费观看 | 91精品第一页 | 精品国内自产拍在线观看视频 | 黄色免费高清视频 | 玖玖精品视频 | 免费在线激情视频 | 国产成人一区二区三区在线观看 | 干 操 插 | 久久最新视频 | 六月色 | 黄a网站 | 日韩精品一区二区三区水蜜桃 | 日韩欧美在线观看一区 | 色av色av色av | 日本公妇色中文字幕 | 日韩欧美视频一区二区三区 | 国产亚洲精品久久网站 | 婷婷狠狠操 | 91尤物国产尤物福利在线播放 | 91看片淫黄大片在线播放 | 91精品在线视频观看 | 韩国av三级 | 天天天天色综合 |