How does the surface sensor calibrator control system operate?

Release time:2022-12-13    This article is read 5371 Times

How does the surface sensor calibrator control system operate?

The Control system can automatically connect to the Surface sensor calibrator, monitor the data of the surface calibrator in real time and control the Surface sensor calibrator.

The Surface sensor calibrator Control System supports the following functions:

1. Display and refresh the device PV value in real time.

2. Display the device Sv value and set the device Sv value.

3. Automatically calculate and display the 10-minute fluctuation of the equipment.

4. Start/stop Surface calibrator temperature control.

5. Start/stop Surface calibrator autotune.

6. Display the surface probe calibrator curve in real time, and support zooming and panning functions. 

System Configuration

? After the system starts, enter the Surface sensor calibrator control configuration interface.

? In the configuration interface, select the communication port of the surface probe calibrator device according to the serial port connection.

? The communication rate of the surface calibrator is 115200, and the communication format of the surface probe calibrator is 8N1, which does not need to be modified.

? Click the start button, the system will automatically connect to the Surface sensor calibrator.

surface sensor calibrator control system

Surface sensor calibrator connection

? The system enters the Surface sensor calibrator connection interface and starts online inspection of surface calibrator  equipment.

? If the serial port of the surface probe calibrator program is occupied, it will return to the configuration interface, and an error message of "communication port is occupied" will be prompted.

surface sensor calibrator control system

If the Surface sensor calibrator program does not respond, it will return to the configuration interface and prompt the error message "Surface calibrator does not respond".

surface sensor calibrator control system

If the Surface sensor calibrator program connection is successful, it will enter the monitoring main interface.

Monitoring main interface

? After the system enters the monitoring main interface, it will display Pv value, Sv value, 10-minute fluctuation and record curve information.

? The system collects Pv value data in real time and refreshes it in real time on the main interface.

? The system displays the current Sv value, and the Sv value can be modified by setting the temperature button.

? When the system starts 10 minutes later, it starts to display the 10-minute fluctuation of the surface probe calibrator. If the system startup time is less than 10 minutes, it will display --.

? The system collects data every 5s, and adds the data to the historical record. The 10-minute fluctuation data is obtained by calculating the historical record data. After the historical record data is added, it will be displayed in the historical record curve in real time.

surface sensor calibrator control system

Record curve

The temperature curve of the last 10 minutes is displayed in real time in the record curve. When new data is added to the history record, the record curve will be refreshed in real time.

? In the record curve, click the enter interactive mode button on the upper right to enter the record curve interactive mode. In the interactive mode, the record curve can be zoomed in, zoomed out, panned, displayed all data, refreshed data, and displayed/hidden prompt information.

surface sensor calibrator control system

? Curve zoom in and zoom out: In the interactive mode, scroll the mouse wheel up to zoom out the curve. Roll the wheel down to zoom in on the curve.

? Curve translation: In interactive mode, hold down the left mouse button and drag to perform curve translation.

? Show All: In the interactive mode, click the Show All button to automatically zoom the curve to ensure that all data can be displayed correctly in the chart.

? Refresh chart: In the interactive mode, click Refresh Chart, and the system will refresh the data to ensure that the newly collected data can be displayed correctly.

? Show/Hide Prompt Information: In interactive mode, uncheck the "Show Prompt Information" check box, and the prompt information of each data collection point will no longer be displayed. Select the "Show Prompt Information" check box, and when you move the mouse, it will automatically prompt the collection date, collection time and data value of the latest collection point.

Surface sensor calibrator Control

? Surface probe calibrator control operation support: start/stop temperature control, start/stop setting, modify set value Sv.

? Start/stop temperature control: Click the start temperature control button, and the system enters the temperature control mode. In the temperature control mode, only the operation of stopping the temperature control can be performed, and other verification furnace control operations cannot be performed. Click the stop temperature control button to pop up a confirmation dialog box for stopping temperature control, click OK to exit the temperature control mode.

surface sensor calibrator control system

surface sensor calibrator control system

Start/stop tuning: Click the start tuning button, the system will pop up a confirmation dialog box, enter the self-tuning password to enter the self-tuning mode. In the self-tuning mode, only the operation of stopping the self-tuning can be performed, and other verification furnace control operations cannot be performed. Click the stop tuning button to exit the auto-tuning mode.

Note: Please use the self-tuning function after consulting the manufacturer.

surface sensor calibrator control system

surface sensor calibrator control system

surface sensor calibrator control system

Modify the set value Sv: click the set temperature button, a dialog box for modifying the set temperature will pop up, modify the set temperature value, and click the set button to modify the set temperature of the surface probe calibrator.

surface sensor calibrator control system

Note: When the system is in the temperature control mode/setting mode, the set value Sv cannot be modified, it must be modified after the temperature control/auto-tuning is stopped.

Stop monitoring: click the stop monitoring button, a dialog box of stopping monitoring will pop up, click stop, and the system will exit the monitoring interface.

surface sensor calibrator control system


How does the surface sensor calibrator control system operate?
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:The difference between liquid calibration bath and dry block calibratornext:Invitation: Join Us at World Metrology Day 2026 Conference in Singapore

Contact us

DEARTO QR codeHeadquarter Address Tai'an High-tech Development Zone,  Shandong Province 
Telephon :+86 0538-5089056  +86 13953856217 
Fax : +86 0538-5059718 
After sale:+86 0538-5050959
Website : www.tadt.com.cn 
E-mail   :  tadtzdh@dearto.cn

Copyright? Tai'an Detu Automation Instrument Co., Ltd.             Lu ICP 14024757-1           Business license inquiry

主站蜘蛛池模板: 欧美综合在线视频 | av播放在线 | 天天操天天干天天 | 天天综合五月天 | 久久任你操 | 久久网站最新地址 | 欧美小视频在线 | 狂野欧美激情性xxxx欧美 | 视频一区亚洲 | 超碰大片 | 国产精品成人免费一区久久羞羞 | 免费三级黄 | 色婷婷免费| 日韩免费一级电影 | 99精品国产99久久久久久福利 | 在线免费中文字幕 | 9999激情 | 射久久 | 制服丝袜在线 | 日日操日日插 | 欧美成人h版在线观看 | 亚洲精品国产麻豆 | 91精选在线观看 | 免费色av| 亚洲少妇久久 | 亚洲日本中文字幕在线观看 | 日韩电影中文 | 91麻豆产精品久久久久久 | 99国产视频在线 | 国产精品24小时在线观看 | 日本特黄特色aaa大片免费 | 日本久久久久久久久久久 | 久久久久久毛片 | 1024手机基地在线观看 | 天天插天天爽 | 国产中文字幕免费 | 一本一道久久a久久精品蜜桃 | 香蕉视频国产在线观看 | 99精品欧美一区二区三区 | 91在线网站| 亚洲精品视频在线观看免费 | 香蕉视频国产在线观看 | 亚洲精品福利在线 | 欧美一区,二区 | 人人插人人艹 | www.天天干.com | 久久视频免费在线 | 国产亚洲综合在线 | 天天操天天干天天玩 | 国产裸体视频网站 | 成年人免费看的视频 | 99人成在线观看视频 | 激情自拍av | 日本成人a | 夜色资源网 | 亚洲国产精品va在线看黑人 | 91成版人在线观看入口 | 九九热只有精品 | 天天综合中文 | 久久爱导航 | 亚洲精品视频 | 精品视频成人 | 亚洲视频第一页 | 久热av在线 | 亚洲精品小区久久久久久 | 91香蕉视频好色先生 | 天天操操操操操 | 国产在线一线 | 国产精品一区二区三区观看 | 国产高清精品在线 | 国产精品久久久久久影院 | 欧美精品视| 97色在线 | 国产精品美女久久久 | 不卡的av片 | 国产午夜精品在线 | 四虎成人精品永久免费av九九 | 丁香六月婷婷综合 | 久久99亚洲精品久久久久 | 欧美日韩二三区 | 久操免费视频 | 国内精品视频久久 | 日本韩国精品在线 | 人成免费网站 | 一级黄色a视频 | 日韩成人免费在线电影 | 一本一本久久aa综合精品 | 亚洲天堂网在线视频观看 | 天天插日日插 | 超碰在线个人 | 黄色小说在线观看视频 | 欧美色伊人 | 国产又粗又猛又色 | 国产免费作爱视频 | 成人亚洲综合 | 日韩成年视频 | 在线观看成人av | 69人人| 国产人成精品一区二区三 |