Common Methods of Thermocouple Calibration

Release time:2023-1-10    This article is read 5741 Times

During the use of thermocouples, sometimes the hot end is oxidized, corroded or the thermocouple material recrystallizes at high temperature, which changes the characteristics of the thermocouple, and then the measurement error becomes larger and larger. In order to ensure a certain accuracy in temperature measurement, Thermocouples must be calibrated periodically to detect changes in the thermocouple. When the change exceeds the specified error range, you can replace the thermocouple wire or cut off a section of the hot end of the original thermocouple, and use it after re-welding. It must also be recalibrated when in use.

Thermocouple Calibration

There are usually three methods for thermocouple calibration, namely bipolar method (direct comparison method), unipolar method (same-named pole method) and differential method.


1. Bipolar method

The method of directly comparing the standard and the thermocouple to be calibrated is called the bipolar method.

Advantages: The method is simple and easy to operate. Different types of thermocouples can be calibrated in the same furnace; the measuring ends of the thermocouples are not bundled on the same isothermal surface in the furnace; the number of measurements is small, usually two to four times.

Disadvantages: The free end of the thermocouple is required to be 0 degrees, otherwise it should be corrected; when the model of the standard device is different from that of the thermocouple to be calibrated, due to the large difference in the electric thermal potential at the same temperature, special attention should be paid to the galvanometer during operation. Damage; because the change of furnace temperature directly affects the calibration accuracy, the furnace temperature control is strictly required (for one cycle of reading, for the calibration of industrial thermocouples, the change of furnace temperature should not exceed 1°C).


2. Unipolar method

After binding the standard and the thermocouple to be calibrated (must be of the same type) into the furnace, the calibration method of measuring the differential thermoelectric potential between the standard and the thermocouple with the same name (positive and positive, negative and negative) is called unipolar method,

Advantages: fast reading, and can directly read the difference, easy to calculate, not strict requirements on furnace temperature control during calibration (fluctuations of ±10°C are allowed). temperature (not 0°C) without correction.

Disadvantages: The standard and calibrated thermocouples must be of the same type. For different types of thermocouples, the unipolar method cannot be used. The measuring ends of the standard and calibrated thermocouples must be bound firmly. Improper binding is prone to errors. It is a small potential, so the quality requirements for electrical measuring instruments, transfer switches and connecting wires are very high, otherwise the calibration error will be increased, the wiring is more complicated, and a positive and negative transfer switch is required. When switching from the measurement furnace to the measurement In the case of extreme thermoelectric potential with the same name, due to the sudden change from large potential measurement to small potential measurement, care should be taken not to damage the galvanometer during operation.


3.Differential method

The standard device and the thermocouple to be calibrated (same type) are connected in reverse series into the temperature calibration furnace, and the test method of the thermoelectric potential difference during the direct measurement is called the differential method.

Advantages: fast reading, can directly read the difference, simple calculation, simple wiring, and the reading is half of the unipolar method, the free end of the thermocouple only needs to be kept at room temperature (not limited to 0°C), and no correction is required. During the inspection, the temperature control in the furnace is not strictly required, and it is allowed to fluctuate within ±5°C of the calibration point.

Disadvantages: The standard device and the thermocouple to be calibrated must be of the same type; when measuring the differential potential, the positive pole of the thermocouple to be calibrated must be connected to the positive terminal of the potentiometer; The quality requirements of switches and connecting wires are high; otherwise, the calibration error will be increased. When changing from temperature calibration furnace temperature to measurement of differential potential, due to sudden changes in large potential measurement and small potential measurement, attention should also be paid to the operation The galvanometer is not damaged.

There are several methods for calibrating thermocouples, which should be determined according to the needs in actual application, and special attention should be paid to the regulation of furnace temperature change speed when calibrating thermocouples.

Common Methods of Thermocouple Calibration
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:Common Problems and Solutions in ThermoCouple Calibrationnext:Invitation: Join Us at World Metrology Day 2026 Conference in Singapore

Contact us

DEARTO QR codeHeadquarter Address Tai'an High-tech Development Zone,  Shandong Province 
Telephon :+86 0538-5089056  +86 13953856217 
Fax : +86 0538-5059718 
After sale:+86 0538-5050959
Website : www.tadt.com.cn 
E-mail   :  tadtzdh@dearto.cn

Copyright? Tai'an Detu Automation Instrument Co., Ltd.             Lu ICP 14024757-1           Business license inquiry

主站蜘蛛池模板: 久久深夜 | 91自拍成人| www.久久视频 | 一区在线播放 | 丁香激情五月 | 久久国产一区二区 | 夜夜骑天天操 | 久草在线这里只有精品 | 国产精品视频内 | 91成年视频| 欧美在线视频日韩 | 夜夜夜夜夜夜操 | 91xav| 在线观看你懂的网站 | 99精品视频中文字幕 | 色婷婷综合久色 | 久久99久久99精品 | 亚洲精品在线资源 | 久久99精品国产99久久 | 激情网在线观看 | 天天操夜夜逼 | 99国内精品久久久久久久 | 天天综合网天天综合色 | 激情自拍av | 最新av网址在线观看 | 天堂av在线网址 | 中国成人一区 | 日韩影视精品 | 99精品在线 | 国产视频91在线 | 在线观看黄网站 | 女人久久久久 | 亚洲黄色区 | 五月天综合网站 | 91视频下载 | 狠狠干成人 | 欧美性色综合网站 | 国产视频亚洲视频 | 九九久久国产精品 | 国产亚洲精品久久久久久久久久 | av中文天堂| 成人精品影视 | 97超碰免费| 最近中文字幕国语免费av | 国产丝袜一区二区三区 | 久久精品中文字幕 | 久草免费在线视频观看 | 亚洲黄色app | 激情在线网站 | 婷婷激情五月 | 国产精品久久久毛片 | 欧美午夜精品久久久久 | 毛片视频电影 | 午夜精品av| 很黄很污的视频网站 | av一级一片 | 日韩在线一级 | 国产福利在线不卡 | 天天躁日日躁狠狠躁av中文 | av中文字幕在线免费观看 | 婷婷5月激情5月 | 免费日韩视 | 国产又黄又猛又粗 | 99久久精品久久久久久清纯 | 99精品免费久久久久久久久日本 | 国产成人精品一区二区三区福利 | 97超碰在线免费观看 | 色香蕉网 | 国产成本人视频在线观看 | 亚洲精品播放 | 国产美女视频免费 | 欧美做受高潮 | 久久人人爽人人片av | 国产高清视频在线播放 | 亚洲国产片 | 偷拍久久久 | 国产精品午夜8888 | 国产精品久久网站 | 免费av的网站 | 国产黄色理论片 | 欧洲精品久久久久毛片完整版 | 久久免费视频网站 | 在线精品观看国产 | 日本久久久久久久久久 | 中文在线免费视频 | 99热在线观看 | 国产精品久久久久久久久久99 | 久久久精品99 | 日本最新一区二区三区 | 天天拍天天色 | 久久免费视频3 | 免费在线激情电影 | 狠狠色丁香久久婷婷综合五月 | 久久国产精品99久久久久久丝袜 | 人人草在线视频 | 97超碰精品 | 九九免费在线看完整版 | 国产精品18videosex性欧美 | 日韩视频免费观看高清完整版在线 |