How does the surface sensor calibrator control system operate?

2022-12-13 This article is read 5349 Times

How does the surface sensor calibrator control system operate?

The Control system can automatically connect to the Surface sensor calibrator, monitor the data of the surface calibrator in real time and control the Surface sensor calibrator.

The Surface sensor calibrator Control System supports the following functions:

1. Display and refresh the device PV value in real time.

2. Display the device Sv value and set the device Sv value.

3. Automatically calculate and display the 10-minute fluctuation of the equipment.

4. Start/stop Surface calibrator temperature control.

5. Start/stop Surface calibrator autotune.

6. Display the surface probe calibrator curve in real time, and support zooming and panning functions. 

System Configuration

? After the system starts, enter the Surface sensor calibrator control configuration interface.

? In the configuration interface, select the communication port of the surface probe calibrator device according to the serial port connection.

? The communication rate of the surface calibrator is 115200, and the communication format of the surface probe calibrator is 8N1, which does not need to be modified.

? Click the start button, the system will automatically connect to the Surface sensor calibrator.

surface sensor calibrator control system

Surface sensor calibrator connection

? The system enters the Surface sensor calibrator connection interface and starts online inspection of surface calibrator  equipment.

? If the serial port of the surface probe calibrator program is occupied, it will return to the configuration interface, and an error message of "communication port is occupied" will be prompted.

surface sensor calibrator control system

If the Surface sensor calibrator program does not respond, it will return to the configuration interface and prompt the error message "Surface calibrator does not respond".

surface sensor calibrator control system

If the Surface sensor calibrator program connection is successful, it will enter the monitoring main interface.

Monitoring main interface

? After the system enters the monitoring main interface, it will display Pv value, Sv value, 10-minute fluctuation and record curve information.

? The system collects Pv value data in real time and refreshes it in real time on the main interface.

? The system displays the current Sv value, and the Sv value can be modified by setting the temperature button.

? When the system starts 10 minutes later, it starts to display the 10-minute fluctuation of the surface probe calibrator. If the system startup time is less than 10 minutes, it will display --.

? The system collects data every 5s, and adds the data to the historical record. The 10-minute fluctuation data is obtained by calculating the historical record data. After the historical record data is added, it will be displayed in the historical record curve in real time.

surface sensor calibrator control system

Record curve

The temperature curve of the last 10 minutes is displayed in real time in the record curve. When new data is added to the history record, the record curve will be refreshed in real time.

? In the record curve, click the enter interactive mode button on the upper right to enter the record curve interactive mode. In the interactive mode, the record curve can be zoomed in, zoomed out, panned, displayed all data, refreshed data, and displayed/hidden prompt information.

surface sensor calibrator control system

? Curve zoom in and zoom out: In the interactive mode, scroll the mouse wheel up to zoom out the curve. Roll the wheel down to zoom in on the curve.

? Curve translation: In interactive mode, hold down the left mouse button and drag to perform curve translation.

? Show All: In the interactive mode, click the Show All button to automatically zoom the curve to ensure that all data can be displayed correctly in the chart.

? Refresh chart: In the interactive mode, click Refresh Chart, and the system will refresh the data to ensure that the newly collected data can be displayed correctly.

? Show/Hide Prompt Information: In interactive mode, uncheck the "Show Prompt Information" check box, and the prompt information of each data collection point will no longer be displayed. Select the "Show Prompt Information" check box, and when you move the mouse, it will automatically prompt the collection date, collection time and data value of the latest collection point.

Surface sensor calibrator Control

? Surface probe calibrator control operation support: start/stop temperature control, start/stop setting, modify set value Sv.

? Start/stop temperature control: Click the start temperature control button, and the system enters the temperature control mode. In the temperature control mode, only the operation of stopping the temperature control can be performed, and other verification furnace control operations cannot be performed. Click the stop temperature control button to pop up a confirmation dialog box for stopping temperature control, click OK to exit the temperature control mode.

surface sensor calibrator control system

surface sensor calibrator control system

Start/stop tuning: Click the start tuning button, the system will pop up a confirmation dialog box, enter the self-tuning password to enter the self-tuning mode. In the self-tuning mode, only the operation of stopping the self-tuning can be performed, and other verification furnace control operations cannot be performed. Click the stop tuning button to exit the auto-tuning mode.

Note: Please use the self-tuning function after consulting the manufacturer.

surface sensor calibrator control system

surface sensor calibrator control system

surface sensor calibrator control system

Modify the set value Sv: click the set temperature button, a dialog box for modifying the set temperature will pop up, modify the set temperature value, and click the set button to modify the set temperature of the surface probe calibrator.

surface sensor calibrator control system

Note: When the system is in the temperature control mode/setting mode, the set value Sv cannot be modified, it must be modified after the temperature control/auto-tuning is stopped.

Stop monitoring: click the stop monitoring button, a dialog box of stopping monitoring will pop up, click stop, and the system will exit the monitoring interface.

surface sensor calibrator control system


How does the surface sensor calibrator control system operate?
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:The difference between liquid calibration bath and dry block calibratornext:Invitation: Join Us at World Metrology Day 2026 Conference in Singapore

Copyright? Tai'an Dearto Automation Instrument Co., Ltd.

Chinese

主站蜘蛛池模板: 欧美日本不卡视频 | 国产精品成人国产乱一区 | 国产精品美女久久久久久久久久久 | 日日夜夜精品免费观看 | 精品亚洲成a人在线观看 | 国产一区二区在线观看视频 | 亚洲精品91天天久久人人 | 久久综合狠狠综合久久激情 | 久久久久亚洲国产 | 色偷偷中文字幕 | 国产精品一区二区在线 | 丁香激情综合久久伊人久久 | 中文字幕精品一区久久久久 | 中文在线字幕免费观看 | 五月开心婷婷网 | 91综合视频在线观看 | 超碰公开在线观看 | 去看片 | 久久精品视 | 国产一区免费在线观看 | 国产香蕉视频在线播放 | 成人av网站在线播放 | 国产成人精品综合久久久 | 日韩最新在线 | 成人在线免费观看网站 | 国产成人久久av | 国产96av| 国产视频久久久久 | 国产高清视频在线播放 | 成人黄色免费在线观看 | 九九热在线观看 | 中文av资源站 | 三级免费黄色 | 在线免费观看国产黄色 | av在线播放不卡 | 亚州国产精品视频 | 久草干| 依人成人综合网 | 亚洲成人av电影在线 | 国产精品久久一区二区三区, | 亚洲精品国产高清 | 色婷婷综合视频在线观看 | 欧美国产一区在线 | 精品乱码一区二区三四区 | 天天操夜夜操天天射 | 在线免费高清一区二区三区 | 99精品视频在线免费观看 | 伊人天堂久久 | 国产日产高清dvd碟片 | 中文在线亚洲 | 夜夜爽夜夜操 | 精品国产乱码久久久久久久 | 中文字幕av在线不卡 | 男女拍拍免费视频 | 色婷婷88av视频一二三区 | 日韩精品视频网站 | 国产最新视频在线观看 | 国产精品18久久久久久久久久久久 | 又黄又刺激视频 | 狠狠操操操 | 久久高清片 | 欧美一级特黄高清视频 | 中文字幕免费高清在线观看 | 91视频免费| 欧美日韩1区 | 久久成人国产精品免费软件 | 久久综合狠狠综合久久激情 | 国产视频精品久久 | 欧美日韩观看 | 日韩精品电影在线播放 | 天天性天天草 | 国产视频一区二区在线播放 | 日韩三级久久 | 亚洲人在线 | 亚洲精色 | 国产视频不卡一区 | 在线免费成人 | 亚洲aⅴ在线 | 成人黄色大片在线免费观看 | 日韩精品一区二区在线 | 国产精品二区在线 | 久久久综合九色合综国产精品 | av黄在线播放 | 久久久激情网 | 午夜精品久久久99热福利 | 国产成人久久精品一区二区三区 | 热精品| 色资源中文字幕 | 五月婷婷在线观看 | 国产精品女教师 | 国产亚洲aⅴaaaaaa毛片 | 久久久久久中文字幕 | 久久久精品一区二区三区 | 国产成人精品av | 五月花丁香婷婷 | 国产在线精品国自产拍影院 | 99高清视频有精品视频 | 成人黄色在线播放 | 欧美在线一二 |