久久成熟I在线免费观看的avI色婷婷激婷婷情综天天I国内精品福利视频I国产一区二区高清视频I久久福利国产I国语黄色片I五月花婷婷

Solution

How does the surface sensor calibrator control system operate?

2022-12-13 This article is read 5334 Times

How does the surface sensor calibrator control system operate?

The Control system can automatically connect to the Surface sensor calibrator, monitor the data of the surface calibrator in real time and control the Surface sensor calibrator.

The Surface sensor calibrator Control System supports the following functions:

1. Display and refresh the device PV value in real time.

2. Display the device Sv value and set the device Sv value.

3. Automatically calculate and display the 10-minute fluctuation of the equipment.

4. Start/stop Surface calibrator temperature control.

5. Start/stop Surface calibrator autotune.

6. Display the surface probe calibrator curve in real time, and support zooming and panning functions. 

System Configuration

? After the system starts, enter the Surface sensor calibrator control configuration interface.

? In the configuration interface, select the communication port of the surface probe calibrator device according to the serial port connection.

? The communication rate of the surface calibrator is 115200, and the communication format of the surface probe calibrator is 8N1, which does not need to be modified.

? Click the start button, the system will automatically connect to the Surface sensor calibrator.

surface sensor calibrator control system

Surface sensor calibrator connection

? The system enters the Surface sensor calibrator connection interface and starts online inspection of surface calibrator  equipment.

? If the serial port of the surface probe calibrator program is occupied, it will return to the configuration interface, and an error message of "communication port is occupied" will be prompted.

surface sensor calibrator control system

If the Surface sensor calibrator program does not respond, it will return to the configuration interface and prompt the error message "Surface calibrator does not respond".

surface sensor calibrator control system

If the Surface sensor calibrator program connection is successful, it will enter the monitoring main interface.

Monitoring main interface

? After the system enters the monitoring main interface, it will display Pv value, Sv value, 10-minute fluctuation and record curve information.

? The system collects Pv value data in real time and refreshes it in real time on the main interface.

? The system displays the current Sv value, and the Sv value can be modified by setting the temperature button.

? When the system starts 10 minutes later, it starts to display the 10-minute fluctuation of the surface probe calibrator. If the system startup time is less than 10 minutes, it will display --.

? The system collects data every 5s, and adds the data to the historical record. The 10-minute fluctuation data is obtained by calculating the historical record data. After the historical record data is added, it will be displayed in the historical record curve in real time.

surface sensor calibrator control system

Record curve

The temperature curve of the last 10 minutes is displayed in real time in the record curve. When new data is added to the history record, the record curve will be refreshed in real time.

? In the record curve, click the enter interactive mode button on the upper right to enter the record curve interactive mode. In the interactive mode, the record curve can be zoomed in, zoomed out, panned, displayed all data, refreshed data, and displayed/hidden prompt information.

surface sensor calibrator control system

? Curve zoom in and zoom out: In the interactive mode, scroll the mouse wheel up to zoom out the curve. Roll the wheel down to zoom in on the curve.

? Curve translation: In interactive mode, hold down the left mouse button and drag to perform curve translation.

? Show All: In the interactive mode, click the Show All button to automatically zoom the curve to ensure that all data can be displayed correctly in the chart.

? Refresh chart: In the interactive mode, click Refresh Chart, and the system will refresh the data to ensure that the newly collected data can be displayed correctly.

? Show/Hide Prompt Information: In interactive mode, uncheck the "Show Prompt Information" check box, and the prompt information of each data collection point will no longer be displayed. Select the "Show Prompt Information" check box, and when you move the mouse, it will automatically prompt the collection date, collection time and data value of the latest collection point.

Surface sensor calibrator Control

? Surface probe calibrator control operation support: start/stop temperature control, start/stop setting, modify set value Sv.

? Start/stop temperature control: Click the start temperature control button, and the system enters the temperature control mode. In the temperature control mode, only the operation of stopping the temperature control can be performed, and other verification furnace control operations cannot be performed. Click the stop temperature control button to pop up a confirmation dialog box for stopping temperature control, click OK to exit the temperature control mode.

surface sensor calibrator control system

surface sensor calibrator control system

Start/stop tuning: Click the start tuning button, the system will pop up a confirmation dialog box, enter the self-tuning password to enter the self-tuning mode. In the self-tuning mode, only the operation of stopping the self-tuning can be performed, and other verification furnace control operations cannot be performed. Click the stop tuning button to exit the auto-tuning mode.

Note: Please use the self-tuning function after consulting the manufacturer.

surface sensor calibrator control system

surface sensor calibrator control system

surface sensor calibrator control system

Modify the set value Sv: click the set temperature button, a dialog box for modifying the set temperature will pop up, modify the set temperature value, and click the set button to modify the set temperature of the surface probe calibrator.

surface sensor calibrator control system

Note: When the system is in the temperature control mode/setting mode, the set value Sv cannot be modified, it must be modified after the temperature control/auto-tuning is stopped.

Stop monitoring: click the stop monitoring button, a dialog box of stopping monitoring will pop up, click stop, and the system will exit the monitoring interface.

surface sensor calibrator control system


How does the surface sensor calibrator control system operate?
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:The difference between liquid calibration bath and dry block calibratornext:Invitation: Join Us at World Metrology Day 2026 Conference in Singapore

Copyright? Tai'an Dearto Automation Instrument Co., Ltd.

Chinese

主站蜘蛛池模板: 国产精品美女视频 | 91精选在线观看 | 一区二区不卡视频在线观看 | av在线观 | 精品人人人人 | 又爽又黄又无遮挡网站动态图 | 99精品福利 | 亚洲免费成人 | 一级免费黄视频 | 国产一区二区精品久久91 | 欧美日韩免费看 | 五月天综合婷婷 | 中文字幕日韩电影 | 久久精品123 | 国产精品久久在线 | 国产91在线看 | 国产香蕉97碰碰久久人人 | 91片黄在线观 | 亚洲欧美国产精品va在线观看 | 国产一区二区三区四区在线 | 在线超碰av| 91av大全 | 国产精品专区在线观看 | 久久艹影院 | av大全在线观看 | 亚洲日本一区二区在线 | 国产精品ssss在线亚洲 | 日韩中文字幕在线看 | 人人射人人澡 | 婷久久| 狠狠干婷婷色 | 91中文字幕一区 | 成人免费xxxxxx视频 | 天天躁日日躁狠狠躁av中文 | 午夜影视剧场 | 激情五月婷婷丁香 | 久久国产精品视频观看 | 亚洲成人午夜在线 | 国产最顶级的黄色片在线免费观看 | 亚洲精品在线二区 | 亚洲国产欧洲综合997久久, | 国产黄色播放 | 午夜精品一区二区三区视频免费看 | 中文在线字幕观看电影 | 国产精品999久久久 久产久精国产品 | 精品免费视频123区 午夜久久成人 | 国产精品大片在线观看 | 亚洲一级片av | 亚洲国产午夜精品 | 久久天天拍 | 色婷婷综合视频在线观看 | 国产淫a| 亚洲高清在线观看视频 | 麻豆视频免费在线播放 | 亚洲日本精品视频 | 亚洲成人av电影 | 中文字幕中文字幕在线中文字幕三区 | 久章草在线观看 | 国产精品成人一区 | 色资源中文字幕 | 韩日三级在线 | 国产伦理久久精品久久久久_ | 99在线免费观看视频 | 99久久国产免费,99久久国产免费大片 | 97在线公开视频 | 91精品999 | www.久久婷婷 | 国产小视频你懂的在线 | 日日噜噜噜噜夜夜爽亚洲精品 | 视频在线亚洲 | 去干成人网 | 久草在线最新免费 | 91资源在线播放 | 亚洲精品女人 | 天天操天天能 | 亚洲一区视频在线播放 | 天天射综合网视频 | 国产九色91 | 国产精品免费人成网站 | 伊人五月婷 | 久久色视频 | 久久伊人五月天 | 亚洲精品美女在线观看播放 | 最新国产精品拍自在线播放 | 91av电影在线观看 | 天天操夜夜曰 | 91九色蝌蚪视频在线 | 天天摸天天操天天舔 | 首页中文字幕 | 久久免费精品国产 | 国内精品视频一区二区三区八戒 | 国产麻豆精品一区二区 | 欧美精品一区二区在线播放 | 国产成人精品电影久久久 | 四虎国产精品免费观看视频优播 | 国产91丝袜在线播放动漫 | 国产区欧美 | 韩国av电影网 | 日韩高清激情 |