Thermal Knowledge | Dew point and relative humidity conversion of precision dew point instrument

2024-8-27 This article is read 4659 Times

1. Conversion formula

 JJF 1012-2007 In Terms and Definitions of Humidity and Moisture Measurement, relative humidity is defined as the percentage [13] of the mole fraction of water vapor in moisture to the mole fraction of saturated water vapor under the same temperature and pressure conditions. When the moisture is regarded as an ideal gas, the conversion formula of dew point and relative humidity can be deduced from the gas equation of state and the Dalton partial pressure theorem

 圖片 1.png

 For the relative humidity of the measured gas,% RH; f is the value added coefficient of the measured gas (a function of temperature and pressure of the measured gas, calculated by the Hardy formula); Td is the measured gas dew point or frost point, ℃ DP; T is the measured gas temperature; ℃; p is the measured gas pressure; Pa; es is the vapor pressure of pure water surface or ice surface (a function of temperature, here calculated by the Sonntag formula), Pa.

 Water surface and ice surface correspond to dew point and frost point, respectively, and are calculated by different saturated steam pressure formula and value-added coefficient formula. Overcooled water with a temperature lower than 0℃ on the ground is an unstable state, so when Td is less than 0℃ DP, it is generally considered as the frost point, unless the instrument has the function of distinguishing the dew point and expressing the dew point, it is calculated as the dew point.

In addition, when the temperature T is less than 0℃, the cold water surface (dew point) is used for meteorological monitoring, ice surface (frost point).


2. The influence of the value-added coefficient

In order to determine the influence of the value-added coefficient in the dew point and relative humidity conversion, first a set of different dew point parameters under normal temperature and atmospheric pressure substitution formula (1) to calculate the relative humidity, and then the group of parameters under the default value coefficient 1 substitution formula (1), compare the two calculation results, as shown in table 1, known that the difference between the two at room temperature and atmospheric pressure is less than 0.01% RH, generally ignore the value-added coefficient. Because the pressure only affects the value-added coefficient, the pressure is not measured when converting the dew point and relative humidity at room temperature and normal pressure.

 Table 1. Impact of the value-added coefficient

圖片 2.png

Then different temperature, pressure and dew point parameters are added into the formula (1) to calculate the relative humidity, and the results are shown in Figure 1, showing the effect of the value-added coefficient on the conversion results of dew point and relative humidity at room temperature, low temperature increases slightly and at high temperature, especially at high and low pressure, more than 1% RH.

圖片 3.png

Figure 1 Effect of value-added coefficient on dew point and relative humidity conversion results under different temperature and pressure conditions


3. Verification of the relative humidity conversion results of the precision dew point instrument

 Select many commonly used precision dew point instrument, test on double temperature and double pressure humidity generator, test the temperature, dew point and pressure of the precision dew point instrument (for no pressure, the actual pressure of the humidity generator test room), calculate the calculation results with the relative humidity value of the dew point meter, to verify the accuracy of the relative humidity conversion results of the dew point instrument.

The test was conducted at atmospheric pressure (102.10 kPa), with the double temperature, double pressure and humidity generator value as the standard value, the positive dew point at normal temperature was 20℃ and 80.0% RH, and the negative dew point was 20℃ and 10.0% RH. The test site at negative temperature is-30℃, 80.0% RH (calculated by ice surface). The test validation results are presented in Tables 2 and and 3.

Table 2. Validation results at room temperature

圖片 4.png

 Table 3 Validation results at negative temperature

圖片 5.png

 As can be seen from Table 2, the difference of the relative humidity of all dew points except one instrument (OPV) does not exceed 0.03% RH as calculated by equation (1). However, the relative humidity display value of the instrument OPV is quite different from the value calculated by formula (1), because the resolution of dew point and temperature is 0.1℃, while the resolution of the other instruments is 0.01℃ (the actual resolution inside the instrument is even higher).

 In negative dew point, four with dew point identification function of dew point instrument, there are three instrument relative humidity display value and according to (1) calculation value is not more than 0.01% RH, and the new S8000 Remote instrument relative humidity display value and (1) the calculation of the difference is larger, the reason is that the instrument dew frost point identification function is not perfect, the dew point as frost point calculation.

 The other four dew point instruments do not have the function of dew frost point identification (although some have observation Windows, but in fact it is difficult to identify dew frost points only by the human eye) and cannot be applied to negative dew points. For comparison, the test data are also listed here. After calculation, the relative humidity of these four instruments is calculated according to the frost point in the negative dew point, but the actual value is closer to the dew point. Of course, the formation of dew / frost has a lot to do with the test conditions, and is not invariable, so the instrument without the function of dew point recognition can theoretically be used for negative dew point measurement.

 In addition, from table 2, many dew frost point identification function, although the negative dew point relative humidity display value and adopt the standard conversion method of frost point calculation formula is very consistent, but the relative humidity actual value, shows that although the instrument built-in frost point and relative humidity conversion formula is correct, but they of dew frost point discrimination is wrong, cause the result is completely wrong.

There are few precision dew point instruments to measure relative humidity at negative temperature. An instrument is tested here and the pumping method is used, and the results are shown in Table 3 (during calculation, es (T), the ice saturated water vapor pressure is used in formula (1), and the display gear of the instrument is set as "RH" rather than "RHWHO"). According to Table 3, the relative humidity display value of the instrument is consistent with the value obtained by the standard conversion method (only 0.01% RH) and consistent with the actual value of relative humidity.

4. Conclusion

 According to the conversion formula of dew point and relative humidity, the value-added coefficient has little influence on the conversion result of dew point and relative humidity under the room temperature and pressure, and has some influence at high temperature and low pressure, which cannot be ignored. Because the pressure only affects the value-added coefficient, the pressure can not be measured when converting the dew point and relative humidity at normal temperature and normal pressure.

 This formula is used to verify the built-in relative humidity conversion results of many commonly used precision dew point instruments. The results show that the deviation between the relative humidity display value of the instrument with 0.01℃ resolution and the calculated value is not more than 0.03% RH, while the deviation between the relative humidity display value of the instrument with 0.1℃ resolution is large. In the negative dew point, in the nominal dew point instrument with the dew frost point recognition function, there are three instruments with a deviation not more than 0.01% RH, and the other one has a large deviation. It can be seen that the 0.1℃ resolution instrument is difficult to meet the requirements as a relative humidity standard.

 For the instrument with the discrimination function of dew frost point, the results show that the difference between the relative humidity and the frost point is great, and the actual relative humidity, so it cannot be used for the measurement of relative humidity at negative dew point.

The above conclusions have important reference significance for the practical application of precision outpoint instrument.


Thermal Knowledge | Dew point and relative humidity conversion of precision dew point instrument
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:News | Congratulations on the successful convening of the Symposium on Advances in Temperature Metrology Research and High Temperature Detection Application Technology and the Annual Meeting of 2024 Membersnext:Invitation: Join Us at World Metrology Day 2026 Conference in Singapore

Copyright? Tai'an Dearto Automation Instrument Co., Ltd.

Chinese

主站蜘蛛池模板: 国产自产高清不卡 | 久久高清视频免费 | 超碰人人草| 九九色在线观看 | 国产精品成人一区二区三区吃奶 | 天天干天天色2020 | 天天干天天碰 | 成人性生交大片免费观看网站 | 五月天婷婷视频 | 亚洲美女免费视频 | 久草在线视频免费资源观看 | 日女人电影| 日韩精品免费一线在线观看 | av在线一级 | 久久最新视频 | 日韩在线一区二区免费 | 亚洲天堂自拍视频 | 国产精品激情偷乱一区二区∴ | 手机看国产毛片 | 99精品视频免费全部在线 | 日韩色区 | 国产成人精品亚洲精品 | 高清av免费观看 | 久热久草在线 | 91视频3p | 久久精品国产久精国产 | 韩国一区二区三区视频 | 日本三级中文字幕在线观看 | 欧美一级小视频 | 国产视频精选在线 | 亚洲精品美女久久久 | 亚洲黄色成人 | 色橹橹欧美在线观看视频高清 | 成年人免费电影 | 久久精品艹| 亚洲国产操| 五月婷婷中文字幕 | 亚洲午夜大片 | 欧美做受xxx | 91麻豆国产福利在线观看 | 91九色在线| 四虎国产精品免费观看视频优播 | 天天射天天爱天天干 | 欧美日韩国产一二 | 91视频91自拍 | 久久婷婷影视 | 久草免费看| 国产在线91在线电影 | 91精品麻豆 | 91视频 - 114av| 九九有精品 | 天天曰| 国产91全国探花系列在线播放 | 国产xxxx| 亚洲日韩中文字幕在线播放 | 国产综合精品一区二区三区 | 日韩中文字幕一区 | 国产成人在线观看 | 成人免费电影 | 国产无限资源在线观看 | 国产片免费在线观看视频 | 又色又爽的网站 | 精品国产乱码 | 国产色妞影院wwwxxx | 69av网| 亚洲日本在线视频观看 | 一级片在线| 天天色天天干天天色 | 天天操天天添天天吹 | 天天做日日做天天爽视频免费 | 色黄www小说| 狠狠狠色丁香综合久久天下网 | 少妇做爰k8经典 | 日韩av福利在线 | 日韩av一区二区在线播放 | 日韩在线播放av | 欧美成人视 | 国产精品女主播一区二区三区 | 狂野欧美激情性xxxx欧美 | 国产字幕在线看 | 亚洲精品乱码久久久久v最新版 | 成人黄在线 | 亚洲最大av在线播放 | 黄色视屏免费在线观看 | 国产精品成人一区二区 | 亚洲成人av一区二区 | 99久久久久成人国产免费 | 九九热.com | av片中文字幕 | 国产小视频福利在线 | 亚洲欧美在线观看视频 | 免费毛片aaaaaa | 97视频精品| 午夜av一区二区三区 | 国产精品日韩高清 | 久草手机视频 | 婷婷在线免费观看 | 九九久久久久99精品 | 日韩av电影国产 |